Explanation to Firmware Version Numbering E20 Fieldbus NORMAL VERSION Version 1 to 16: out warning is not used Version 17 to 40: out warning is used - Unit starts after power on with the last active program SPECIAL VERSION A Version 61 to 80: same as version 21 to 40, but without warning - Version for replacing a unit with software version 1 to 16. - Sometimes the warning signal is controlled by the PLC. At units with version 1 to 16 this had no function. If such a unit is replaced with version 17 to 40 it will cause the PLC to stop because of the warning. For this situation please use version 61 to 80. SPECIAL VERSION B Version 81 to 99: same as version 21 to 40, but without program number storing - At normal and special version A the program number is always stored when switching between programs. If the switching is very often (1 million), it destroys the memory. - After power up the unit starts with program 255. SPECIAL VERSION AB Version 50 to 59: combination of special versions A and B - After power up the unit starts with program 255. - This version does not store the program number. - Out warning signal is not used. NEW VERSION INCLUDES THE FOUR VERSIONS Beginning with Version Vx3579x3 the behaviour of the Software could be set at "system parameter 0"